IE-iMcV-VDSL2-LANextender
Operation Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - Operation Manual

IE-iMcV-VDSL2-LANextender Operation Manual

Strona 2 - Warranty

7 LINK Quality Link Quality is defined by 4 values: 8,4,2,1. The four green LEDs form a binary code indicating the MAX bandwidth the VDSL line can s

Strona 3

8 Overflow activity will be less if Flow Control is enabled. Flow Control or Pause will limit the number of dropped Ethernet frames by reducing the c

Strona 4

9 Maximum Bandwidth IE-iMcV-VDSL2-LANextender Link LEDS The standard single pair IE-iMcV-VDSL2-LANextender unit will provide the following Rate/Reach

Strona 5

10 The unit will automatically adjust to reach the best bandwidth performance for the physical line it is connected to. The associated LED display wi

Strona 6

11 Primary Line Protector NOTE If VDSL line is connected to the outside plant, the wire entry point to the building must have primary line protec

Strona 7

12 Appendix—Pinouts RJ-45 Data Port Pinout (MDI) The following table lists the pin configuration for the RJ-45 Data connector. Pin Signal 1 Transmit+

Strona 8

13 Troubleshooting The most common failure of a VDSL line is its slow degradation over time due to aging of the line or increased line noise as addi

Strona 9 - Negotiation

14 Specifications Standards: ITU-TG.993.1 ITU-TG.997.1 GR-1089-Core Secondary Line Protection Power Consumption (Typical): 550 mA @ 5 V Operating Temp

Strona 10

15 IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); +32-16-550880 (Europe) Fax: (949) 465-3020

Strona 11

16 Certifications CE: The products described herein comply with the Council Directive on Electromagnetic Compatibility (2004/108/EC). For further

Strona 12

ii FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device, pursu

Strona 13

19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com © 2010 IMC Networks. All r

Strona 14

iii Table of Contents FCC Radio Frequency Interference Statement ... ii Warranty...

Strona 15

1 About the IE-iMcV-VDSL2-LANextender The IE-iMcV-VDSL2-LANextender enables LAN and Campus network managers, and service providers, to use an existing

Strona 16

2 Installing IE-iMcV-VDSL2-LANextender Modules If the VDSL line is connected to the outside plant, the wire entry point to the building must have prim

Strona 17

3 LED Operation LED Function (VDSL) RAI The Remote Alarm Indication led is YELLOW when the unit at the far end of the Unit has an alarm FL Fault Loop

Strona 18

4 DIP Switch Settings The DIP Switches allow the user to configure most of the module features before installing the unit. These also enable the Host

Strona 19

5 Host (CO) Module Configuration To allow the HOST (CO) Control Office IE-iMcV-VDSL2-LANextender module to manage the remotely connected CPE IE-iMcV-V

Strona 20

6 Selective Advertising Selective Advertising (DIP Switch #7) when used in combination with Auto Negotiation, advertises only the configured speed and